משדר לחות במדידת שמן

EplusE-EE36-360

משדר לחות במדידת שמן

EE36Transmitter for moisture in oil measurementphysical quantities measured are water activity aw and temperature T. With these quantities EE36 calculates the water content (ppm) in mineral transformer oils. Calculation of water content in non-mineral transformer oils and lubrication oils can be accomplished by downloading specific parameters of the oil. The measured and the calculated values are available on two free scaleable and configurable analogue outputs. In addition, an optional relay output can be used for alarms and process control. •    ppm (mass of water / mass of oil)•    aw (actual water content as fraction of the water content in the saturated oil) aw = 0 corresponds to water-free oil, while aw = 1 describes fully saturated oil.